Service Manual Service Manual SDS1000D Digital Storage Oscilloscope June 2011 SIGLENT Technologies Co., Ltd.
Service Manual Hard Ware Frequency Counter Reading resolution 6 Bytes Range DC Couple, 10Hz to MAX Bandwidth Sign
Service Manual Chapter 2 Prepare for Use This chapter includes the following contents: ● General Inspecting ● Power-On Inspecting ● Connect the
Service Manual Power-On Inspection Normal operating voltage for DS1000CA series digital oscilloscope is the range of 100-240VRMS with the frequency f
Service Manual Auto Setup SDS1000D Series Digital Storage Oscilloscopes have auto setup function, which can identify the type of waveform and adjust
Service Manual Chapter 3 Performance Test This chapter includes the following contents: Interface Test USB Host USB Device RS-232
Service Manual USB Device Test Purpose: Test if the USB Device interface works normally through EasyScope for SDS1000D series oscilloscope. Tool
Service Manual Picture 3-6 EasyScope connect setting 4. Press “UTILITY” page3/4 IO Setting, select the Baud as 38400 5. Click “Connect”
Service Manual Specification Test Purpose: Test if some specifications are in the specified range. Table 3-2 require instruments Description Minim
Service Manual Test Trigger Sensitivity Steps:::: 1、Press the button “DEFAULT/SETUP”, and set the VOLT/DIV to 500mv/div, set SEC/DIV to
Service Manual Picture 4-2 Calibrating 4. After the calibration finished, Press “SINGLE” key to exit. Picture 4-3 Calibration succeed interface
Service Manual Notice Notices:::: ● Don’t disassemble the products except the work need. ● Disassemble only can be done by qualified person.
Service Manual Disassemble and Assemble Back Rind Picture 5-2 Disassemble and Assemble back rind 1 图 5-3 Disassemble and Assemble back rind 2 D
Service Manual Disassemble and Assemble Top Cover Board Picture 5-5 Disassemble and Assemble top cover board Disassemble steps: 1. Back out the
Service Manual Disassemble and Assemble power board Picture 5-7 Disassemble and Assemble power board Disassemble steps: 1. Back out the four bo
Service Manual Disassemble and Assemble Main board Picture 5-9 Disassemble and Assemble main board Disassemble steps: 1. Back out the five bolts
Service Manual ●●●● Avoid Exposed Circuitry. Do not touch exposed connections and components when power is present. ●●●● Do Not Operate With Suspec
Service Manual Disassemble and Assemble Keyboard Picture 5-11 Disassemble and Assemble keyboard Disassemble steps: 1. Back out the four bolts ○
Service Manual Drive. Store Data Success! : Save setup data, waveform data or picture data to the internal of the oscilloscope or USB flash succe
Service Manual Chapter 7 Updating Parts SIGLENT Provide some replaceable parts in order to maintain or update for users. Please see as the followin
Service Manual Catalogue Document Summarize...
Service Manual Horizontal System Real Time Sampling Rate Single Channel:500MSa/s,Double Channel: 250MSa/s Equivalent Sampling Rate 50GSa/s Measu